Saline volume required to achieve peristaltic intraluminal pressure during leak testing of canine colotomies, using two methods of luminal occlusion.


Journal

Open veterinary journal
ISSN: 2218-6050
Titre abrégé: Open Vet J
Pays: Libya
ID NLM: 101653182

Informations de publication

Date de publication:
May 2024
Historique:
received: 22 01 2024
accepted: 22 04 2024
medline: 28 6 2024
pubmed: 28 6 2024
entrez: 28 6 2024
Statut: ppublish

Résumé

No studies have appeared in the literature evaluating the intraluminal volume of injected saline in the canine colon for performing leak tests in colotomy incisions. To determine the volume of the injected intraluminal saline necessary to achieve an intraluminal pressure of 17.3 cm H Fresh colon was obtained from 8 canine cadavers and divided into 10 cm segments. A 3 cm antimesenteric colonic incision was performed at each intestinal segment which was closed using a 3-0 polydioxanone suture in a simple continuous pattern. Each colonic construct was occluded with Doyen intestinal forceps or by digital pressure and a leak test was performed by saline infusion. The saline volume needed to achieve a predetermined intraluminal pressure of 17.3 cm H The mean volume of injected saline with the Doyen intestinal forceps occlusion (20.4 ± 8.2 ml) was significantly larger than that of the digital occlusion technique (17.5 ± 6.8 ml) [ For 10 cm canine colonic constructs containing a closed colotomy, saline volumes of 20.4 ml with Doyen occlusion and 17.5 ml with digital occlusion can be utilized to achieve intraluminal pressures of 17.3 cm H

Sections du résumé

Background UNASSIGNED
No studies have appeared in the literature evaluating the intraluminal volume of injected saline in the canine colon for performing leak tests in colotomy incisions.
Aim UNASSIGNED
To determine the volume of the injected intraluminal saline necessary to achieve an intraluminal pressure of 17.3 cm H
Methods UNASSIGNED
Fresh colon was obtained from 8 canine cadavers and divided into 10 cm segments. A 3 cm antimesenteric colonic incision was performed at each intestinal segment which was closed using a 3-0 polydioxanone suture in a simple continuous pattern. Each colonic construct was occluded with Doyen intestinal forceps or by digital pressure and a leak test was performed by saline infusion. The saline volume needed to achieve a predetermined intraluminal pressure of 17.3 cm H
Results UNASSIGNED
The mean volume of injected saline with the Doyen intestinal forceps occlusion (20.4 ± 8.2 ml) was significantly larger than that of the digital occlusion technique (17.5 ± 6.8 ml) [
Conclusion UNASSIGNED
For 10 cm canine colonic constructs containing a closed colotomy, saline volumes of 20.4 ml with Doyen occlusion and 17.5 ml with digital occlusion can be utilized to achieve intraluminal pressures of 17.3 cm H

Identifiants

pubmed: 38938420
doi: 10.5455/OVJ.2024.v14.i5.6
pii: OVJ-14-1130
pmc: PMC11199764
doi:

Substances chimiques

Saline Solution 0

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

1130-1134

Déclaration de conflit d'intérêts

The authors declare that there is no conflict of interest.

Auteurs

Eleni Prastiti (E)

Limassol Veterinary Clinic, Limassol, Cyprus.

Ioannis Savvas (I)

Companion Animal Clinic, School of Veterinary Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.

Vasileia Angelou (V)

Companion Animal Clinic, School of Veterinary Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.

Lysimachos G Papazoglou (LG)

Companion Animal Clinic, School of Veterinary Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.

Articles similaires

Robotic Surgical Procedures Animals Humans Telemedicine Models, Animal

Odour generalisation and detection dog training.

Lyn Caldicott, Thomas W Pike, Helen E Zulch et al.
1.00
Animals Odorants Dogs Generalization, Psychological Smell
Animals TOR Serine-Threonine Kinases Colorectal Neoplasms Colitis Mice
Animals Tail Swine Behavior, Animal Animal Husbandry

Classifications MeSH