True volumetric counting of CD34+ cells using flow cytometry.
CD34 +
Flow cytometry
ISHAGE
True volumetric system
Journal
Journal of immunological methods
ISSN: 1872-7905
Titre abrégé: J Immunol Methods
Pays: Netherlands
ID NLM: 1305440
Informations de publication
Date de publication:
Apr 2024
Apr 2024
Historique:
received:
06
10
2023
revised:
26
01
2024
accepted:
20
02
2024
pubmed:
24
2
2024
medline:
24
2
2024
entrez:
23
2
2024
Statut:
ppublish
Résumé
While the single-platform flow cytometric CD34+ cell counting method is the preferred choice to predict the yield of mobilized peripheral blood stem cells, most flow cytometers lack the ability of hematology counter analyzers to perform volumetric counting. However, one of the problems using reference microbeads is the vanishing counting bead phenomenon. This phenomenon results in a drop in microbeads concentration and reduces the total and relative number of beads in calibration procedures. In the last years, flow cytometers including a volumetric system to quantify cells have been developed and may represent a promising alternative to enumerate CD34+ cells avoiding the use of beads. In this study we have used a direct true volumetric counting of CD34+ cells under continuous flow pump to overcome potential drawbacks with impact in rare cell analysis. To confirm this hypothesis, we have compared the results of CD34+ cell enumeration using non-volumetric vs. volumetric systems with FC500 (Beckman Coulter) and Attune NxT (ThermoFisher) flow cytometers, respectively, in mobilized peripheral blood samples. No statistically significant differences were observed between measurements of CD34+ cells using beads, when the FC500 and Attune NxT absolute counting values were compared, or when CD34+ counts were compared on the Attune NxT, either using or not using beads. Linear regressions to study the relationship between volumetric and non-volumetric CD34+ counts confirmed the accuracy of each method. Bland-Altman test showed agreement between both methods. Our data showed that CD34+ cell enumeration using a volumetric system is comparable with current counting systems. This method represents an alternative with the advantage of the simplification of sample preparation and the reduction of the analysis subjectivity.
Identifiants
pubmed: 38395105
pii: S0022-1759(24)00034-6
doi: 10.1016/j.jim.2024.113649
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
113649Informations de copyright
Copyright © 2024 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest M.D.W. and J.A.B. work for Thermo Fisher Scientific, which is in the business of selling flow cytometers and flow cytometry reagents. The rest of authors declare no potential conflicts of interest.