Interventional cardiac catheterization in neonates and premature infants with congenital heart disease: a single center experience.

children complications congenital heart disease interventional cardiology

Journal

The Turkish journal of pediatrics
ISSN: 2791-6421
Titre abrégé: Turk J Pediatr
Pays: Turkey
ID NLM: 0417505

Informations de publication

Date de publication:
2023
Historique:
medline: 11 1 2024
pubmed: 11 1 2024
entrez: 11 1 2024
Statut: ppublish

Résumé

The increased survival of patients with congenital heart disease over the last three decades has been associated with improvements in diagnosis and treatment. This study aimed to evaluate therapeutic interventional catheterization, outcomes and complications of these procedures in neonates and premature infants. In this study, therapeutic catheterization procedures performed on neonates and premature infants with congenital heart disease at a university hospital between February 2000 and October 2019 were retrospectively evaluated. A total of 322 procedures were performed on 279 neonates and 26 premature infants. Of the patients, 217 (67.4%) were male. The median age of the patients was 8 days (interquartile range [IQR] 2-20) and the median body weight was 3050 g (IQR 2900-3600). The most common procedures were balloon atrial septostomy, balloon aortic angioplasty, balloon pulmonary valvuloplasty and balloon aortic valvuloplasty (35.4%, 20.8%, 18.3% and 12.4% respectively). The most common diagnoses were transposition of the great arteries, coarctation of the aorta, pulmonary stenosis and aortic stenosis (26.7%, 19.3%, 15.2% and 11.5% respectively). Most procedures, 274 (85.1%), were successful. Complications were observed in 74 procedures (23%). Of these complications, 45 (14%) were minor and 29 (9%) were major. The most common complication was transient dysrhythmia (6.9%). There was no significant relationship between body weight, age and the rate of complications. However, longer procedure time and fluoroscopy time were associated with higher complication rates (p < 0.05). Four procedurerelated deaths were observed. Procedure-related complications are higher in the neonatal period. Although the complication rate varies according to the type of procedure, longer fluoroscopy time and procedure duration are associated with an increased complication rate. Procedures performed with the right indications, appropriate equipment and by experienced teams will play a key role in reducing complication rates.

Sections du résumé

BACKGROUND BACKGROUND
The increased survival of patients with congenital heart disease over the last three decades has been associated with improvements in diagnosis and treatment. This study aimed to evaluate therapeutic interventional catheterization, outcomes and complications of these procedures in neonates and premature infants.
METHODS METHODS
In this study, therapeutic catheterization procedures performed on neonates and premature infants with congenital heart disease at a university hospital between February 2000 and October 2019 were retrospectively evaluated.
RESULTS RESULTS
A total of 322 procedures were performed on 279 neonates and 26 premature infants. Of the patients, 217 (67.4%) were male. The median age of the patients was 8 days (interquartile range [IQR] 2-20) and the median body weight was 3050 g (IQR 2900-3600). The most common procedures were balloon atrial septostomy, balloon aortic angioplasty, balloon pulmonary valvuloplasty and balloon aortic valvuloplasty (35.4%, 20.8%, 18.3% and 12.4% respectively). The most common diagnoses were transposition of the great arteries, coarctation of the aorta, pulmonary stenosis and aortic stenosis (26.7%, 19.3%, 15.2% and 11.5% respectively). Most procedures, 274 (85.1%), were successful. Complications were observed in 74 procedures (23%). Of these complications, 45 (14%) were minor and 29 (9%) were major. The most common complication was transient dysrhythmia (6.9%). There was no significant relationship between body weight, age and the rate of complications. However, longer procedure time and fluoroscopy time were associated with higher complication rates (p < 0.05). Four procedurerelated deaths were observed.
CONCLUSION CONCLUSIONS
Procedure-related complications are higher in the neonatal period. Although the complication rate varies according to the type of procedure, longer fluoroscopy time and procedure duration are associated with an increased complication rate. Procedures performed with the right indications, appropriate equipment and by experienced teams will play a key role in reducing complication rates.

Identifiants

pubmed: 38204308
pii: 2645
doi: 10.24953/turkjped.2022.1064
doi:
pii:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

939-948

Auteurs

Nazan Ülgen Tekerek (NÜ)

Division of Pediatric Intensive Care, Department of Pediatrics, Akdeniz University Faculty of Medicine, Antalya.

Hayrettin Hakan Aykan (HH)

Division of Pediatric Cardiology, Department of Pediatrics, Hacettepe University Faculty of Medicine, Ankara.

Ayşe Ünal Yüksekgönül (AÜ)

Division of Pediatric Cardiology, Department of Pediatrics, Hacettepe University Faculty of Medicine, Ankara.

İlker Ertuğrul (İ)

Division of Pediatric Cardiology, Department of Pediatrics, Hacettepe University Faculty of Medicine, Ankara.

Ebru Aypar (E)

Division of Pediatric Cardiology, Department of Pediatrics, Hacettepe University Faculty of Medicine, Ankara.

Dursun Alehan (D)

Division of Pediatric Cardiology, Department of Pediatrics, Hacettepe University Faculty of Medicine, Ankara.

Alpay Çeliker (A)

Division of Pediatric Cardiology, Department of Pediatrics, Koc University Faculty of Medicine, İstanbul, Türkiye.

Tevfik Karagöz (T)

Division of Pediatric Cardiology, Department of Pediatrics, Hacettepe University Faculty of Medicine, Ankara.

Classifications MeSH