Assessment of Dust, Chemical, Microbiological Pollutions and Microclimatic Parameters of Indoor Air in Sports Facilities.
air quality
bioaerosol
biodiversity
chemical contamination
microclimatic parameters
particulate matter
sports facilities
Journal
International journal of environmental research and public health
ISSN: 1660-4601
Titre abrégé: Int J Environ Res Public Health
Pays: Switzerland
ID NLM: 101238455
Informations de publication
Date de publication:
14 01 2023
14 01 2023
Historique:
received:
06
12
2022
revised:
11
01
2023
accepted:
12
01
2023
entrez:
21
1
2023
pubmed:
22
1
2023
medline:
25
1
2023
Statut:
epublish
Résumé
The aim of this study was to analyse the quality of indoor air in sport facilities in one of the sport centres in Poland with respect to microclimatic parameters (temperature, humidity, and air flow velocity), particulate matter concentrations (PM10, PM4, PM2.5, and PM1), gas concentrations (oxygen, ozone, hydrogen sulphide, sulphur dioxide, volatile organic compounds, and benzopyrene), and microbial contamination (the total number of bacteria, specifically staphylococci, including Staphylococcus aureus, haemolytic bacteria, Enterobacteriaceae, Pseudomonas fluorescens, actinomycetes, and the total number of fungi and xerophilic fungi). Measurements were made three times in May 2022 at 28 sampling points in 5 different sporting areas (the climbing wall, swimming pool, swimming pool changing room, and basketball and badminton courts) depending on the time of day (morning or afternoon) and on the outside building. The obtained results were compared with the standards for air quality in sports facilities. The air temperature (21−31 °C) was at the upper limit of thermal comfort, while the air humidity (RH < 40%) in the sports halls in most of the locations was below demanded values. The values for dust pollution in all rooms, except the swimming pool, exceeded the permissible limits, especially in the afternoons. Climatic conditions correlated with a high concentration of dust in the indoor air. Particulate matter concentrations of all fractions exceeded the WHO guidelines in all researched premises; the largest exceedances of standards occurred for PM2.5 (five-fold) and for PM10 (two-fold). There were no exceedances of gaseous pollutant concentrations in the air, except for benzopyrene, which resulted from the influence of the outside air. The total number of bacteria (5.1 × 101−2.0 × 104 CFU m−3) and fungi (3.0 × 101−3.75 × 102 CFU m−3) was exceeded in the changing room and the climbing wall hall. An increased number of staphylococci in the afternoon was associated with a large number of people training. The increased concentration of xerophilic fungi in the air correlated with the high dust content and low air humidity. Along with the increase in the number of users in the afternoon and their activities, the concentration of dust (several times) and microorganisms (1−2 log) in the air increased by several times and 1−2 log, respectively. The present study indicates which air quality parameters should be monitored and provides guidelines on how to increase the comfort of those who practice sports and work in sports facilities.
Identifiants
pubmed: 36674305
pii: ijerph20021551
doi: 10.3390/ijerph20021551
pmc: PMC9865041
pii:
doi:
Substances chimiques
Dust
0
Particulate Matter
0
Sulfur Dioxide
0UZA3422Q4
Benzopyrenes
0
Air Pollutants
0
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Langues
eng
Sous-ensembles de citation
IM
Références
Int J Syst Evol Microbiol. 2018 Sep;68(9):2924-2929
pubmed: 30070622
J Strength Cond Res. 2008 Jan;22(1):2-5
pubmed: 18296948
Environ Sci Pollut Res Int. 2014 Nov;21(21):12390-402
pubmed: 24938814
Int J Environ Res Public Health. 2022 Apr 15;19(8):
pubmed: 35457694
Environ Sci Pollut Res Int. 2021 Oct;28(37):52576-52586
pubmed: 34018112
Indoor Air. 2004;14 Suppl 7:92-101
pubmed: 15330777
Biol Direct. 2019 Nov 13;14(1):20
pubmed: 31722729
J Thorac Dis. 2017 Mar;9(3):444-447
pubmed: 28449440
SAGE Open Med Case Rep. 2019 May 09;7:2050313X19844154
pubmed: 31105940
Air Qual Atmos Health. 2016;9:533-550
pubmed: 27375795
Med Sci (Paris). 2006 Jun-Jul;22(6-7):589-94
pubmed: 16828033
Indoor Air. 2020 Nov;30(6):1109-1129
pubmed: 32657456
Int J Environ Health Res. 2007 Jun;17(3):197-206
pubmed: 17479383
Int J Hyg Environ Health. 2017 May;220(3):591-603
pubmed: 28174041
Rev Environ Health. 2016 Dec 1;31(4):401-407
pubmed: 27837598
Microorganisms. 2020 Nov 30;8(12):
pubmed: 33266327
J Environ Manage. 2017 Jul 1;196:188-200
pubmed: 28284941
Appl Environ Microbiol. 1996 Feb;62(2):340-6
pubmed: 8593039
Arch Microbiol. 2021 Sep;203(7):4525-4538
pubmed: 34148152
Biotechniques. 2019 Aug;67(2):55-62
pubmed: 31290335
Sci Rep. 2016 Mar 10;6:22943
pubmed: 26961389
Clin Microbiol Rev. 2017 Jan;30(1):409-447
pubmed: 27974412
Sports Med. 2012 Dec 1;42(12):1041-58
pubmed: 23098384
Open Forum Infect Dis. 2020 Jan 19;7(1):ofaa008
pubmed: 32016126
Environ Sci Pollut Res Int. 2017 Jan;24(3):3027-3037
pubmed: 27848134
Sci Total Environ. 2015 Aug 15;524-525:178-86
pubmed: 25897726
Inhal Toxicol. 2003 May;15(6):539-52
pubmed: 12692730
J Appl Microbiol. 2003;95(5):904-12
pubmed: 14633018
J Environ Monit. 2008 May;10(5):648-54
pubmed: 18449402
Int J Syst Evol Microbiol. 2007 Nov;57(Pt 11):2493-2497
pubmed: 17978207
Br J Sports Med. 2001 Aug;35(4):214-22
pubmed: 11477012
Front Microbiol. 2018 Apr 19;9:757
pubmed: 29725324
Toxics. 2022 Oct 20;10(10):
pubmed: 36287906
Circulation. 2004 Jan 6;109(1):71-7
pubmed: 14676145
Trends Microbiol. 2005 Sep;13(9):411-5
pubmed: 16043355