Imaging of the extracranial internal carotid artery in acute ischemic stroke: assessment of stenosis, plaques, and image quality using relaxation-enhanced angiography without contrast and triggering (REACT).

Acute ischemic stroke (AIS) contrast-enhanced magnetic resonance angiography (CE-MRA) extracranial arteries relaxation-enhanced angiography without contrast and triggering (REACT)

Journal

Quantitative imaging in medicine and surgery
ISSN: 2223-4292
Titre abrégé: Quant Imaging Med Surg
Pays: China
ID NLM: 101577942

Informations de publication

Date de publication:
Jul 2022
Historique:
received: 19 11 2021
accepted: 22 03 2022
entrez: 5 7 2022
pubmed: 6 7 2022
medline: 6 7 2022
Statut: ppublish

Résumé

In stroke magnetic resonance imaging (MRI), contrast-enhanced magnetic resonance angiography (CE-MRA) is the clinical standard to depict extracranial arteries but native MRA techniques are of increased interest to facilitate clinical practice. The purpose of this study was to assess the detection of extracranial internal carotid artery (ICA) stenosis and plaques as well as the image quality of cervical carotid arteries between a novel flow-independent relaxation-enhanced angiography without contrast and triggering (REACT) sequence and CE-MRA in acute ischemic stroke (AIS). In this retrospective, single-center study, 105 consecutive patients (65.27±18.74 years, 63 males) were included, who received a standard stroke protocol at 3T in clinical routine including Compressed SENSE (CS) accelerated (factor 4) 3D isotropic REACT (fixed scan time: 02:46 min) and CS accelerated (factor 6) 3D isotropic CE-MRA. Three radiologists independently assessed scans for the presence of extracranial ICA stenosis and plaques (including hyper-/hypointense signal) with concomitant diagnostic confidence using 3-point scales (3= excellent). Vessel quality, artifacts, and image noise of extracranial carotid arteries were subjectively scored on 5-point scales (5= excellent/none). Wilcoxon tests were used for statistical comparison. Considering CE-MRA as the standard of reference, REACT provided a sensitivity of 89.8% and specificity of 95.2% for any and of 93.5% and 95.8% for clinically relevant (≥50%) extracranial ICA stenosis and yielded a to CE-MRA comparable diagnostic confidence [mean ± standard deviation (SD), median (interquartile range): 2.8±0.5, 3 (3-3) Without the use of gadolinium-based contrast agents or triggering, REACT provides a high sensitivity and specificity for extracranial ICA stenosis and a potential improved depiction of adjacent plaques while yielding to CE-MRA comparable vessel quality in a large patient cohort with AIS.

Sections du résumé

Background UNASSIGNED
In stroke magnetic resonance imaging (MRI), contrast-enhanced magnetic resonance angiography (CE-MRA) is the clinical standard to depict extracranial arteries but native MRA techniques are of increased interest to facilitate clinical practice. The purpose of this study was to assess the detection of extracranial internal carotid artery (ICA) stenosis and plaques as well as the image quality of cervical carotid arteries between a novel flow-independent relaxation-enhanced angiography without contrast and triggering (REACT) sequence and CE-MRA in acute ischemic stroke (AIS).
Methods UNASSIGNED
In this retrospective, single-center study, 105 consecutive patients (65.27±18.74 years, 63 males) were included, who received a standard stroke protocol at 3T in clinical routine including Compressed SENSE (CS) accelerated (factor 4) 3D isotropic REACT (fixed scan time: 02:46 min) and CS accelerated (factor 6) 3D isotropic CE-MRA. Three radiologists independently assessed scans for the presence of extracranial ICA stenosis and plaques (including hyper-/hypointense signal) with concomitant diagnostic confidence using 3-point scales (3= excellent). Vessel quality, artifacts, and image noise of extracranial carotid arteries were subjectively scored on 5-point scales (5= excellent/none). Wilcoxon tests were used for statistical comparison.
Results UNASSIGNED
Considering CE-MRA as the standard of reference, REACT provided a sensitivity of 89.8% and specificity of 95.2% for any and of 93.5% and 95.8% for clinically relevant (≥50%) extracranial ICA stenosis and yielded a to CE-MRA comparable diagnostic confidence [mean ± standard deviation (SD), median (interquartile range): 2.8±0.5, 3 (3-3)
Conclusions UNASSIGNED
Without the use of gadolinium-based contrast agents or triggering, REACT provides a high sensitivity and specificity for extracranial ICA stenosis and a potential improved depiction of adjacent plaques while yielding to CE-MRA comparable vessel quality in a large patient cohort with AIS.

Identifiants

pubmed: 35782261
doi: 10.21037/qims-21-1122
pii: qims-12-07-3640
pmc: PMC9246733
doi:

Types de publication

Journal Article

Langues

eng

Pagination

3640-3654

Informations de copyright

2022 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Déclaration de conflit d'intérêts

Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at https://qims.amegroups.com/article/view/10.21037/qims-21-1122/coif). SL, NA, and RJG report that they received research support from Philips Healthcare. JPG and JB are on the speaker’s bureau of Siemens Healthineers. JPG reports that he received payment for expert testimony from Siemens Healthineers. DM, JB, and LP are on the speaker’s bureau of Philips Healthcare. KW is an employee of Philips Healthcare and reports that he holds stock of Philips Healthcare. The other authors have no conflicts of interest to declare.

Références

J Magn Reson Imaging. 2019 Jun;49(7):e164-e175
pubmed: 30267462
Magn Reson Med. 2020 Aug;84(2):825-837
pubmed: 31975432
AJNR Am J Neuroradiol. 2013 Jan;34(1):177-84
pubmed: 22627797
Magn Reson Med Sci. 2018 Jan 10;17(1):3-12
pubmed: 28855470
Magn Reson Med. 2016 May;75(5):2072-7
pubmed: 26072706
Clin Neuroradiol. 2021 Sep;31(3):815-826
pubmed: 33026511
Radiol Res Pract. 2014;2014:508715
pubmed: 24778875
Neuroepidemiology. 2013;40(1):36-41
pubmed: 23075828
Magn Reson Med. 2011 Jan;65(1):96-107
pubmed: 20860006
Radiology. 2008 Jul;248(1):20-43
pubmed: 18566168
Int J Cardiovasc Imaging. 2021 Jan;37(1):315-329
pubmed: 32852711
Eur J Radiol Open. 2020 Jun 07;7:100238
pubmed: 32548214
Radiology. 2007 Mar;242(3):647-9
pubmed: 17213364
Radiology. 2012 Aug;264(2):414-22
pubmed: 22550309
AJNR Am J Neuroradiol. 2018 Sep;39(9):1710-1716
pubmed: 30115678
AJNR Am J Neuroradiol. 2019 Sep;40(9):1529-1537
pubmed: 31395666
Clin Neuroradiol. 2015 Mar;25(1):41-8
pubmed: 24384680
Magn Reson Med. 2009 Dec;62(6):1574-84
pubmed: 19785017
Magn Reson Med. 2007 Dec;58(6):1182-95
pubmed: 17969013
Magn Reson Imaging. 2019 Nov;63:137-146
pubmed: 31425807
World Neurosurg X. 2020 Dec 04;9:100096
pubmed: 33426517
Eur Radiol. 2009 Nov;19(11):2654-62
pubmed: 19449013
J Magn Reson Imaging. 2019 Dec;50(6):1798-1807
pubmed: 31077477
J Cardiovasc Magn Reson. 2017 Jun 30;19(1):48
pubmed: 28662717
Magn Reson Med. 1999 Nov;42(5):952-62
pubmed: 10542355
AJNR Am J Neuroradiol. 2010 Sep;31(8):1395-402
pubmed: 20651015
J Cardiovasc Magn Reson. 2020 Jan 23;22(1):8
pubmed: 31969137
Stroke. 2017 Feb;48(2):513-519
pubmed: 28077454
J Cardiovasc Magn Reson. 2020 Dec 17;22(1):89
pubmed: 33327958
Stroke. 2005 Jan;36(1):38-43
pubmed: 15569881
AJNR Am J Neuroradiol. 2011 Mar;32(3):454-9
pubmed: 21233234
Stroke. 1988 May;19(5):604-7
pubmed: 3363593
Stroke. 2001 Oct;32(10):2282-6
pubmed: 11588314
Radiology. 2015 Dec;277(3):924-5
pubmed: 26599932
J Magn Reson Imaging. 2008 Sep;28(3):543-58
pubmed: 18777528
J Cardiovasc Magn Reson. 2021 Jul 19;23(1):91
pubmed: 34275486
Stroke. 2008 Aug;39(8):2237-48
pubmed: 18556586
Eur Radiol. 2011 Aug;21(8):1667-76
pubmed: 21476128
Neuroimaging Clin N Am. 2011 May;21(2):259-83, x
pubmed: 21640299
Stroke. 2019 Dec;50(12):e344-e418
pubmed: 31662037
Neurol Med Chir (Tokyo). 2021 Mar 15;61(3):193-203
pubmed: 33504734

Auteurs

Ulrike Cornelia Isabel Hoyer (UCI)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Simon Lennartz (S)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Nuran Abdullayev (N)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Florian Fichter (F)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Stephanie T Jünger (ST)

Department of General Neurosurgery, Center for Neurosurgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Lukas Goertz (L)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
Department of General Neurosurgery, Center for Neurosurgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Kai Roman Laukamp (KR)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Roman Johannes Gertz (RJ)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Jan-Peter Grunz (JP)

Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.

Christopher Hohmann (C)

Department III of Internal Medicine, Heart Center, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

David Maintz (D)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Thorsten Persigehl (T)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Christoph Kabbasch (C)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Jan Borggrefe (J)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany.

Kilian Weiss (K)

Philips GmbH, Hamburg, Germany.

Lenhard Pennig (L)

Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Classifications MeSH