2D high resolution vs. 3D whole heart myocardial perfusion cardiovascular magnetic resonance.
coronary artery disease
myocardial ischaemic burden
myocardial perfusion
Journal
European heart journal. Cardiovascular Imaging
ISSN: 2047-2412
Titre abrégé: Eur Heart J Cardiovasc Imaging
Pays: England
ID NLM: 101573788
Informations de publication
Date de publication:
01 06 2022
01 06 2022
Historique:
received:
23
02
2021
pubmed:
29
6
2021
medline:
7
6
2022
entrez:
28
6
2021
Statut:
ppublish
Résumé
Developments in myocardial perfusion cardiovascular magnetic resonance (CMR) allow improvements in spatial resolution and/or myocardial coverage. Whole heart coverage may provide the most accurate assessment of myocardial ischaemic burden, while high spatial resolution is expected to improve detection of subendocardial ischaemia. The objective of this study was to compare myocardial ischaemic burden as depicted by 2D high resolution and 3D whole heart stress myocardial perfusion in patients with coronary artery disease. Thirty-eight patients [age 61 ± 8 (21% female)] underwent 2D high resolution (spatial resolution 1.2 mm2) and 3D whole heart (in-plane spatial resolution 2.3 mm2) stress CMR at 3-T in randomized order. Myocardial ischaemic burden (%) was visually quantified as perfusion defect at peak stress perfusion subtracted from subendocardial myocardial scar and expressed as a percentage of the myocardium. Median myocardial ischaemic burden was significantly higher with 2D high resolution compared with 3D whole heart [16.1 (2.0-30.6) vs. 13.4 (5.2-23.2), P = 0.004]. There was excellent agreement between myocardial ischaemic burden (intraclass correlation coefficient 0.81; P < 0.0001), with mean ratio difference between 2D high resolution vs. 3D whole heart 1.28 ± 0.67 (95% limits of agreement -0.03 to 2.59). When using a 10% threshold for a dichotomous result for presence or absence of significant ischaemia, there was moderate agreement between the methods (κ = 0.58, P < 0.0001). 2D high resolution and 3D whole heart myocardial perfusion stress CMR are comparable for detection of ischaemia. 2D high resolution gives higher values for myocardial ischaemic burden compared with 3D whole heart, suggesting that 2D high resolution is more sensitive for detection of ischaemia.
Identifiants
pubmed: 34179941
pii: 6310334
doi: 10.1093/ehjci/jeab103
pmc: PMC9159745
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
811-819Subventions
Organisme : British Heart Foundation
ID : PG/13/97/30487
Pays : United Kingdom
Organisme : Wellcome Trust
Pays : United Kingdom
Informations de copyright
© The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology.
Références
Am Heart J. 2009 Dec;158(6):910-916.e2
pubmed: 19958856
JACC Cardiovasc Imaging. 2020 Aug;13(8):1815-1833
pubmed: 32762886
Stat Methods Med Res. 1999 Jun;8(2):135-60
pubmed: 10501650
Circ Cardiovasc Imaging. 2015 May;8(5):
pubmed: 25901043
Circulation. 2003 Jun 17;107(23):2900-7
pubmed: 12771008
J Cardiovasc Magn Reson. 2018 Nov 19;20(1):74
pubmed: 30454074
Circ Cardiovasc Imaging. 2014 Jul;7(4):647-54
pubmed: 24867884
JACC Cardiovasc Imaging. 2013 May;6(5):600-9
pubmed: 23582358
J Cardiovasc Magn Reson. 2014 Feb 24;16:19
pubmed: 24565078
Eur Heart J. 2020 Jan 14;41(3):407-477
pubmed: 31504439
Eur Heart J. 2017 Apr 1;38(13):991-998
pubmed: 27141095
J Cardiovasc Magn Reson. 2020 Mar 12;22(1):19
pubmed: 32160925
J Am Coll Cardiol. 2012 Aug 21;60(8):756-65
pubmed: 22818072
J Cardiovasc Magn Reson. 2018 Dec 10;20(1):84
pubmed: 30526627
Circ Cardiovasc Imaging. 2012 May 1;5(3):306-13
pubmed: 22499848
Int J Cardiovasc Imaging. 2018 Apr;34(4):661-669
pubmed: 29197024
J Cardiovasc Magn Reson. 2010 Nov 16;12:66
pubmed: 21080924
Magn Reson Med. 2020 Jun;83(6):1949-1963
pubmed: 31670858
J Cardiovasc Magn Reson. 2020 Feb 24;22(1):17
pubmed: 32089132
J Am Coll Cardiol. 2010 Aug 10;56(7):561-9
pubmed: 20688211
J Cardiovasc Magn Reson. 2016 Jan 14;18:4
pubmed: 26767610
Circulation. 2008 Mar 11;117(10):1283-91
pubmed: 18268144
Eur Heart J Cardiovasc Imaging. 2016 Aug;17(8):900-8
pubmed: 26450417