The Impact of EndoAnchor Penetration on Endograft Structure: First Report of Explant Analysis.
Abdominal
Aortic aneurysm
Endoleak
Endovascular procedures
Journal
EJVES vascular forum
ISSN: 2666-688X
Titre abrégé: EJVES Vasc Forum
Pays: England
ID NLM: 101766732
Informations de publication
Date de publication:
2020
2020
Historique:
received:
13
06
2020
revised:
19
07
2020
accepted:
14
08
2020
entrez:
3
5
2021
pubmed:
4
5
2021
medline:
4
5
2021
Statut:
epublish
Résumé
The adjunctive use of Heli-FX EndoAnchors (EAs) in endovascular aneurysm repair has been proposed for the treatment or prevention of type Ia endoleaks. The aim of this study was to evaluate the impact of the penetration of EAs on endograft textile structure from two aortic endografts that had been explanted for persistent type Ia endoleak despite the implantation of EAs. An Aorfix aortic endograft was implanted in an 85 year old man. Six months later, six EAs were implanted for Ia endoleak. The endograft was explanted as an emergency seven months later for aneurysm rupture. An Endurant II aortic endograft was implanted in an 80 year old man. Seven EAs were implanted 24 months later for type Ia endoleak. A proximal cuff extension with bilateral renal and superior mesenteric artery chimneys was performed 18 months later to treat a persistent type Ia endoleak. Endograft explantation was performed six months later owing to persistent type Ia endoleak and aneurysm sac enlargement. Explant analysis in both cases was performed at GEPROVAS. Systematic analysis of both explants, including the 13 EAs, revealed the following lesions: (1) alteration of textile structure directly linked to several penetrations of the fabric with the same EA and tears of the textile fibres in two cases; (2) tears of the binding threads as the EA had passed through them in five cases; and (3) interactions between EA and endograft stents in four cases. The site of EA penetration into the endograft might contribute to endograft fabric damage and to a loss of stability of the endograft at the level of the aortic neck.
Identifiants
pubmed: 33937895
doi: 10.1016/j.ejvsvf.2020.08.002
pii: S2666-688X(20)30063-0
pmc: PMC8077235
doi:
Types de publication
Journal Article
Langues
eng
Pagination
4-10Informations de copyright
© 2020 The Author(s).
Déclaration de conflit d'intérêts
None.
Références
J Endovasc Ther. 2019 Oct;26(5):704-713
pubmed: 31315502
Eur J Vasc Endovasc Surg. 2020 May;59(5):748-756
pubmed: 32192844
J Vasc Surg. 2017 Jul;66(1):45-52
pubmed: 28274751
J Endovasc Ther. 2019 Feb;26(1):101-104
pubmed: 30572775
Eur J Vasc Endovasc Surg. 2018 Apr;55(4):567-576
pubmed: 29478909
J Vasc Surg. 2012 Jun;55(6):1726-33
pubmed: 22322119
Cardiovasc Intervent Radiol. 2020 Jul;43(7):971-980
pubmed: 32385611
Eur J Vasc Endovasc Surg. 2017 Apr;53(4):458-459
pubmed: 28215931
Eur J Vasc Endovasc Surg. 2019 Jan;57(1):8-93
pubmed: 30528142