Endovascular occlusion balloon-related thrombosis during transvenous lead extraction.


Journal

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
ISSN: 1532-2092
Titre abrégé: Europace
Pays: England
ID NLM: 100883649

Informations de publication

Date de publication:
08 09 2021
Historique:
received: 24 12 2020
accepted: 23 03 2021
pubmed: 7 4 2021
medline: 21 10 2021
entrez: 6 4 2021
Statut: ppublish

Résumé

The aim of this study is to evaluate the incidence, predictors, and outcomes of balloon-related thrombosis (BRT) in patients undergoing transvenous lead extraction (TLE). Use of an endovascular occlusion balloon has improved outcomes of superior vena cava injuries during TLE. Its thrombogenicity in clinical practice is unknown. We prospectively evaluated consecutive patients undergoing prophylactic balloon placement during TLE utilizing two procedural workflows: one with the balloon within the inferior vena cava during the entire case (standard cohort) and one limiting the balloon's dwell time (abbreviated cohort). Intracardiac echocardiography was used to evaluate for significant BRT (thrombus > 1 cm) after TLE. Forty-two patients (21 in each group) were included. Age, left ventricular ejection fraction, procedural indication, number of leads, and lead dwell time were similar between the groups. Balloon dwell time was significantly longer in the standard group (128 ± 74 vs. 25 ± 18 min, P < 0.001) as was BRT (14/21 vs. 1/21, P < 0.001). Mean thrombus length and width in the standard group was 3.99 ± 1.40 and 0.45 ± 0.16 cm, respectively and 5.2 × 0.4 cm in one patient in the abbreviated group. Between patients with and without BRT in the standard group, balloon dwell times were similar (113 ± 64 vs. 156 ± 88 min, P = 0.21). One patient in the standard group had a pulmonary embolism on post-operative Day 3 and was initiated on oral anticoagulation. Prophylactic balloon placement for the entirety of the case is associated with a high incidence of BRT; a finding that is decreased when an abbreviated workflow is utilized.

Identifiants

pubmed: 33822905
pii: 6210705
doi: 10.1093/europace/euab074
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

1472-1478

Informations de copyright

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2021. For permissions, please email: journals.permissions@oup.com.

Auteurs

Naga Venkata K Pothineni (NVK)

Electrophysiology Section, Division of Cardiovascular Medicine, Perelman School of Medicine at the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA.

Cory M Tschabrunn (CM)

Electrophysiology Section, Division of Cardiovascular Medicine, Perelman School of Medicine at the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA.

Roger Carrillo (R)

Palmetto General Hospital, Hialeah, FL, USA.

Robert D Schaller (RD)

Electrophysiology Section, Division of Cardiovascular Medicine, Perelman School of Medicine at the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH