Fracture Injury Risk of the Restrained Mandible to Anterior-Posterior Blunt Impacts.


Journal

Journal of biomechanical engineering
ISSN: 1528-8951
Titre abrégé: J Biomech Eng
Pays: United States
ID NLM: 7909584

Informations de publication

Date de publication:
01 04 2021
Historique:
received: 08 01 2020
pubmed: 10 2 2021
medline: 21 1 2022
entrez: 9 2 2021
Statut: ppublish

Résumé

This study describes the results of anterior-posterior impacts conducted on the mandibles of 22 male postmortem human subjects (PMHSs). The objective of this study was to develop an injury criterion for the mandible based on blunt impact while the jaw was restrained. Previous studies have attempted to characterize the injury risk of blunt impact to the mandible; however, due to the translation of the mandible during impact and a limited number of fractured specimens, previous studies were not able to produce an injury criterion. Blunt impact to a restrained mandible is relevant to a wide array of helmeted individuals, including the military population and sports that require helmets with chinstraps. Therefore, in this study, specimens were positioned with restrained jaws and impacted using a monorail drop tower with a gravity-driven cylindrical impactor. Nineteen of 22 specimens sustained at least one fracture during testing. Injury cases had an average impact energy of 15.0 ± 5.7 J (11.1 ± 4.2 ft-lb) and a fracture force of 2684 ± 726 N (603 ± 163 lbf). Results were used to generate an impactor force based injury criterion through survival analysis. Risk of injury was modeled using a Weibull distribution and a 50% risk of injury was found to occur at approximately 2834 N (637 lbf). The developed injury risk curve can be used to characterize injury to the restrained mandible for future testing and research studies, especially in the development of maxillofacial protective equipment.

Identifiants

pubmed: 33558882
pii: 1098122
doi: 10.1115/1.4050122
pii:
doi:

Types de publication

Journal Article Research Support, U.S. Gov't, Non-P.H.S.

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

Copyright © 2021 by ASME.

Auteurs

Ray W Daniel (RW)

U.S. Army Aeromedical Research Laboratory, 6901 Farrel Road, Fort Rucker, AL 36362; Katmai Health Services, Orlando, FL 32826.

Charles A Weisenbach (CA)

U.S. Army Aeromedical Research Laboratory, 6901 Farrel Road, Fort Rucker, AL 36362; Katmai Health Services, Orlando, FL 32826.

Shannon M McGovern (SM)

U.S. Army Aeromedical Research Laboratory, 6901 Farrel Road, Fort Rucker, AL 36362; Oak Ridge Institute for Science and Education, Oak Ridge, TN 37830.

Tyler F Rooks (TF)

U.S. Army Aeromedical Research Laboratory, 6901 Farrel Road, Fort Rucker, AL 36362.

Valeta Carol Chancey (VC)

U.S. Army Aeromedical Research Laboratory, 6901 Farrel Road, Fort Rucker, AL 36362.

Frederick T Brozoski (FT)

U.S. Army Aeromedical Research Laboratory, 6901 Farrel Road, Fort Rucker, AL 36362.

Articles similaires

Effect of soft tissue thickness on accuracy of conventional and digital implant impression techniques.

Eman Mostafa Awad, Mohamed Maamoun ElSheikh, Azza Abd El Moneim El-Segai
1.00
Dental Impression Technique Humans Dental Implants Computer-Aided Design Dental Impression Materials
Osteogenesis, Distraction Humans Feasibility Studies Augmented Reality Mandible
Animals Magnesium Osteogenesis Cattle Rats

Can Different Impression Techniques Affect the Chewing Efficiency of Mandibular Implant-Retained Overdentures?

Esmail Ahmed Abdel-Gawwad, Mostafa I Fayad, Mohamed Abdullah Quassem et al.
1.00
Humans Denture, Overlay Dental Impression Technique Mastication Dental Prosthesis, Implant-Supported

Classifications MeSH