Résumé
To introduce and demonstrate a software library for time-optimal gradient waveform optimization with a wide range of applications. The software enables direct on-the-fly gradient waveform design on the scanner hardware for multiple vendors. The open-source gradient optimization (GrOpt) toolbox was implemented in C with both Matlab and Python wrappers. The toolbox enables gradient waveforms to be generated based on a set of constraints that define the features and encodings for a given acquisition. The GrOpt optimization routine is based on the alternating direction method of multipliers (ADMM). Additional constraints enable error corrections to be added, or patient comfort and safety to be adressed. A range of applications and compute speed metrics are analyzed. Finally, the method is implemented and tested on scanners from different vendors. Time-optimal gradient waveforms for different pulse sequences and the constraints that define them are shown. Additionally, the ability to add, arbitrary motion (gradient moment) compensation or limit peripheral nerve stimulation is demonstrated. There exists a trade-off between computation time and gradient raster time, but it was observed that acceptable gradient waveforms could be generated in 1-40 ms. Gradient waveforms generated and run on the different scanners were functionally equivalent, and the images were comparable. GrOpt is an open source toolbox that enables on-the-fly optimization of gradient waveform design, subject to a set of defined constraints. GrOpt was presented for a range of imaging applications, analyzed in terms of computational complexity, and implemented to run on the scanner for a multi-vendor demonstration.
Identifiants
pubmed: 33463724
doi: 10.1002/mrm.28384
pmc: PMC7540314
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
3234-3245Informations de copyright
© 2020 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.
Références
Magn Reson Med. 2010 Dec;64(6):1814-20
pubmed: 20878764
Magn Reson Med. 2019 Feb;81(2):989-1003
pubmed: 30394568
Magn Reson Med. 2019 Oct;82(4):1424-1437
pubmed: 31148245
MAGMA. 2018 Oct;31(5):585-597
pubmed: 29603048
Magn Reson Med. 2019 Mar;81(3):1818-1832
pubmed: 30368913
Magn Reson Med. 2004 Jan;51(1):81-92
pubmed: 14705048
Magn Reson Med. 2017 Feb;77(2):717-729
pubmed: 26900872
Magn Reson Med. 2015 Aug;74(2):518-22
pubmed: 25168778
Magn Reson Med. 2019 Jul;82(1):213-224
pubmed: 30859606
J Magn Reson Imaging. 1999 Aug;10(2):183-92
pubmed: 10441023
J Magn Reson. 2015 Dec;261:157-68
pubmed: 26583528
Magn Reson Med. 2018 Feb;79(2):663-672
pubmed: 28444802
Magn Reson Med. 1993 Apr;29(4):498-504
pubmed: 8464366
Magn Reson Med. 1994 Dec;32(6):773-7
pubmed: 7869900
Magn Reson Med. 2014 Dec;72(6):1552-64
pubmed: 24347040