MACACO II test-beam with high energy photons.


Journal

Physics in medicine and biology
ISSN: 1361-6560
Titre abrégé: Phys Med Biol
Pays: England
ID NLM: 0401220

Informations de publication

Date de publication:
22 12 2020
Historique:
pubmed: 30 10 2020
medline: 16 4 2021
entrez: 29 10 2020
Statut: epublish

Résumé

The IRIS group at IFIC Valencia is developing a three-layer Compton camera for treatment monitoring in proton therapy. The system is composed of three detector planes, each made of a [Formula: see text] monolithic crystal coupled to a SiPM array. Having obtained successful results with the first prototype (MACACO) that demonstrated the feasibility of the proposed technology, a second prototype (MACACO II) with improved performance has been developed, and is the subject of this work. The new system has an enhanced detector energy resolution which translates into a higher spatial resolution of the telescope. The image reconstruction method has also been improved with an accurate model of the sensitivity matrix. The device has been tested with high energy photons at the National Accelerator Centre (CNA, Seville). The tests involved a proton beam of 18 MeV impinging on a graphite target, to produce 4.4 MeV photons. Data were taken at different system positions of the telescope with the first detector at 65 and 160 mm from the target, and at different beam intensities. The measurements allowed successful reconstruction of the photon emission distribution at two target positions separated by 5 mm in different telescope configurations. This result was obtained both with data recorded in the first and second telescope planes (two interaction events) and, for the first time in beam experiments, with data recorded in the three planes (three interaction events).

Identifiants

pubmed: 33120374
doi: 10.1088/1361-6560/abc5cd
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

245027

Auteurs

A Ros García (A)

Instituto de Física Corpuscular, CSIC/Universitat de València, Valencia, Spain.

J Barrio (J)

Instituto de Física Corpuscular, CSIC/Universitat de València, Valencia, Spain.

A Etxebeste (A)

Instituto de Física Corpuscular, CSIC/Universitat de València, Valencia, Spain.

J García López (J)

Centro Nacional de Aceleradores (Universidad de Sevilla, CSIC and Junta de Andalucía), 1041092 Sevilla, Spain.
Departamento de Física Atómica, Molecular y Nuclear, Universidad de Sevilla, 1041012 Sevilla, Spain.

M C Jiménez-Ramos (MC)

Centro Nacional de Aceleradores (Universidad de Sevilla, CSIC and Junta de Andalucía), 1041092 Sevilla, Spain.

C Lacasta (C)

Instituto de Física Corpuscular, CSIC/Universitat de València, Valencia, Spain.

E Muñoz (E)

Instituto de Física Corpuscular, CSIC/Universitat de València, Valencia, Spain.

J F Oliver (JF)

Instituto de Física Corpuscular, CSIC/Universitat de València, Valencia, Spain.

J Roser (J)

Instituto de Física Corpuscular, CSIC/Universitat de València, Valencia, Spain.

G Llosá (G)

Instituto de Física Corpuscular, CSIC/Universitat de València, Valencia, Spain.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH