Clinical outcomes of Ankoris toric intraocular lens implantation using a computer-assisted marker system.
Astigmatism
Cataract
IOL
IOL rotation
Toric IOL
Journal
International ophthalmology
ISSN: 1573-2630
Titre abrégé: Int Ophthalmol
Pays: Netherlands
ID NLM: 7904294
Informations de publication
Date de publication:
Dec 2020
Dec 2020
Historique:
received:
15
05
2020
accepted:
17
07
2020
pubmed:
29
7
2020
medline:
22
6
2021
entrez:
29
7
2020
Statut:
ppublish
Résumé
To report the clinical outcomes of patients who underwent cataract surgery with implantation of Ankoris monofocal toric intraocular lens (IOL) (PhysIOL SA, Liège, Belgium) using the Zeiss Callisto Eye (Carl Zeiss AG, Dublin, CA). We conducted a retrospective case series of patients who underwent routine cataract extraction and implantation of Ankoris toric IOL using the Zeiss Callisto eye between January 2018 and December 2018 by four senior surgeons. Patients' medical records were reviewed, and clinical outcomes including postoperative refraction, visual acuity outcomes, IOL position and deviation from planned axis were collected. Fifty-six eyes of 56 patients were included, 48% were female, and the mean age was 70 ± 8 years. Patients with pseudoexfoliation syndrome, glaucoma or keratoconus were excluded from the study. Pre-operative mean corneal astigmatism was 2.38 ± 0.78 diopters (D), and mean implanted IOL cylindrical power was 3.06 ± 1.07 D. IOL rotation 30 days postoperatively was within 5° in 82% of eyes and between 6° and 10° in 10.8% of eyes. Mean postoperative refractive astigmatism 30 days postoperatively was 0.22 ± 0.36 D; in 84% of eyes the postoperative refractive astigmatism was ≤ 0.50 D. IOL rotation significantly increased between day 1 to day 7 postoperatively (1.91 ± 3.15° to 3.18 ± 3.3°, P = 0.001). However, no significant rotation had occurred between day 7 and day 30 postoperatively (P = 0.093). Cataract surgery with implantation of Ankoris monofocal toric IOL using the Zeiss Callisto Eye marking system is predictable and effective in reducing refractive astigmatism.
Identifiants
pubmed: 32720169
doi: 10.1007/s10792-020-01511-4
pii: 10.1007/s10792-020-01511-4
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
3259-3267Références
Ferrer-Blasco T, Montés-Micó R, Peixoto-de-Matos SC, González-Méijome JM, Cerviño A (2009) Prevalence of corneal astigmatism before cataract surgery. J Cataract Refract Surg 35(1):70–75
pubmed: 19101427
Hill W (2008) Expected effects of surgically induced astigmatism on AcrySof toric intraocular lens results. J Cataract Refract Surg 34(3):364–367
pubmed: 18299058
Michelitsch M, Ardjomand N, Vidic B, Wedrich A, Steinwender G (2017) Prevalence and age-related changes of corneal astigmatism in patients before cataract surgery. Ophthalmologe 114(3):247–251
pubmed: 27406230
Kessel L, Andresen J, Tendal B, Erngaard D, Flesner P, Hjortdal J (2016) Toric intraocular lenses in the correction of astigmatism during cataract surgery: a systematic review and meta-analysis. Ophthalmology 123(2):275–286
pubmed: 26601819
Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation- ClinicalKey. https://www-clinicalkey-com.assafh-ez.medlcp.tau.ac.il/#!/content/playContent/1-s2.0-S0886335008006068?returnurl=null&referrer=null . Accessed 1 Oct 2019
CALLISTO eye. https://www.zeiss.com/meditec/int/product-portfolio/surgical-microscopes/ophthalmic-microscopes/callisto-eye-markerless-toric-iol-alignment.html . Accessed 1 Oct 2019
Mayer WJ, Kreutzer T, Dirisamer M, Kern C, Kortuem K, Vounotrypidis E et al (2017) Comparison of visual outcomes, alignment accuracy, and surgical time between 2 methods of corneal marking for toric intraocular lens implantation. J Cataract Refract Surg 43(10):1281–1286
pubmed: 29056301
Zhou F, Jiang W, Lin Z, Li X, Li J, Lin H et al (2019) Comparative meta-analysis of toric intraocular lens alignment accuracy in cataract patients: Image-guided system versus manual marking. J Cataract Refract Surg 45(9):1340–1345
pubmed: 31470944
Vandekerckhove K (2018) Rotational stability of monofocal and trifocal intraocular toric lenses with identical design and material but different surface treatment. J Refract Surg 34(2):84–91
pubmed: 29425386
O’Donnell C, Maldonado-Codina C (2005) Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS Pentacam. Cornea 24(8):920–924
pubmed: 16227833
Lee BS, Chang DF (2018) Comparison of the rotational stability of two toric intraocular lenses in 1273 consecutive eyes. Ophthalmology 125(9):1325–1331
pubmed: 29544960
Abulafia A, Koch DD, Holladay JT, Wang L, Hill W (2018) Pursuing perfection in intraocular lens calculations: IV. Rethinking astigmatism analysis for intraocular lens-based surgery: suggested terminology, analysis, and standards for outcome reports. J Cataract Refract Surg 44(10):1169–1174
pubmed: 30243391
Till JS, Yoder PR, Wilcox TK, Spielman JL (2002) Toric intraocular lens implantation: 100 consecutive cases. J Cataract Refract Surg 28(2):295–301
pubmed: 11821213
Chang DF (2003) Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases. J Cataract Refract Surg 29(5):935–940
pubmed: 12781279
De Silva DJ, Ramkissoon YD, Bloom PA (2006) Evaluation of a toric intraocular lens with a Z-haptic. J Cataract Refract Surg 32(9):1492–1498
pubmed: 16931261
Weinand F, Jung A, Stein A, Pfützner A, Becker R, Pavlovic S (2007) Rotational stability of a single-piece hydrophobic acrylic intraocular lens: new method for high-precision rotation control. J Cataract Refract Surg 33(5):800–803
pubmed: 17466851
Draschl P, Hirnschall N, Luft N, Schuschitz S, Wiesinger J, Rigal K et al (2017) Rotational stability of 2 intraocular lenses with an identical design and different materials. J Cataract Refract Surg 43(2):234–238
pubmed: 28366372
Bozukova D, Werner L, Mamalis N, Gobin L, Pagnoulle C, Floyd A et al (2015) Double-C loop platform in combination with hydrophobic and hydrophilic acrylic intraocular lens materials. J Cataract Refract Surg 41(7):1490–1502
pubmed: 26287887
Webers VSC, Bauer NJC, Visser N, Berendschot TTJM, van den Biggelaar FJHM, Nuijts RMMA (2017) Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery. J Cataract Refract Surg 43(6):781–788
pubmed: 28732612
Elhofi AH, Helaly HA (2015) Comparison between digital and manual marking for toric intraocular lenses: a randomized trial. Medicine (Baltimore) 94(38):e1618
Rastogi A, Khanam S, Goel Y, Thacker P, Kumar P (2018) Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring. Indian J Ophthalmol 66(3):411–415
pubmed: 29480253
pmcid: 5859597
Visser N, Bauer NJC, Nuijts RMMA (2013) Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications. J Cataract Refract Surg 39(4):624–637
pubmed: 23522584
Miyake T, Kamiya K, Amano R, Iida Y, Tsunehiro S, Shimizu K (2014) Long-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatism. J Cataract Refract Surg 40(10):1654–1660
pubmed: 25149554
Inoue Y, Takehara H, Oshika T (2017) Axis misalignment of toric intraocular lens: placement error and postoperative rotation. Ophthalmology 124(9):1424–1425
pubmed: 28647201
Shah GD, Praveen MR, Vasavada AR, Vasavada VA, Rampal G, Shastry LR (2012) Rotational stability of a toric intraocular lens: influence of axial length and alignment in the capsular bag. J Cataract Refract Surg 38(1):54–59
pubmed: 22055077
Zhu X, He W, Zhang K, Lu Y (2016) Factors influencing 1-year rotational stability of AcrySof toric intraocular lenses. Br J Ophthalmol 100(2):263–268
pubmed: 26089212
Prediction of pseudophakic capsular bag diameter based on biometric variables. PubMed—NCBI. https://www-ncbi-nlm-nih-gov.rproxy.tau.ac.il/pubmed/10511938 . Accessed 1 Oct 2019
Vasavada A, Singh R (1998) Relationship between lens and capsular bag size. J Cataract Refract Surg 24(4):547–551
pubmed: 9584254
Oshika T, Fujita Y, Hirota A, Inamura M, Inoue Y, Miyata K et al (2019) Comparison of incidence of repositioning surgery to correct misalignment with three toric intraocular lenses. Eur J Ophthalmol 6:1120672119834469