Intra- and inter-laboratory agreement of the disc diffusion assay for assessing antimicrobial susceptibility of porcine Escherichia coli.
Agreement
Antimicrobial resistance
Disc diffusion
Performance
Precision
Zone-diameter
Journal
Preventive veterinary medicine
ISSN: 1873-1716
Titre abrégé: Prev Vet Med
Pays: Netherlands
ID NLM: 8217463
Informations de publication
Date de publication:
15 Nov 2019
15 Nov 2019
Historique:
received:
29
05
2019
revised:
26
09
2019
accepted:
26
09
2019
pubmed:
7
10
2019
medline:
26
2
2020
entrez:
7
10
2019
Statut:
ppublish
Résumé
Reliable assessment of the susceptibility of animal bacterial pathogens to antimicrobials is of paramount importance in the fight against antimicrobial resistance. This work aims to estimate the repeatability (intra-laboratory agreement) and reproducibility (inter-laboratory agreement) of the disc diffusion assay in veterinary laboratories to understand further if the assay has a role in the surveillance of antimicrobial resistance in animals. Seven major veterinary laboratories from all States in Australia participated, and each tested the same panel of isolates five times at three to four-week intervals, against six antimicrobial agents using Clinical and Laboratory Standards Institute protocols. The panel consisted of twenty different isolates from porcine Escherichia coli from clinical cases and a single reference strain (ATCC 25922). Laboratories were blinded to the identity of the isolates, replicates, and to each other. In total, 4200 inhibition zone diameters (mm) were collected, and analysed descriptively, graphically, and with linear mixed models. Regardless of the laboratories and isolate/antimicrobial combinations, the overall very major error rate (proportion of isolates classified as susceptible when actual status is resistant) was 1.6%; the major error rate (proportion of isolates classified as resistant when actual status is susceptible) was 1.6%; and the 'minor error' rate (proportion of isolates with intermediate susceptibility that measure fully susceptible or resistant or vice versa) was 2.4%. The variation between repeated measurements ranged between 4.4-7.2 mm depending on the antimicrobial agent assessed. The reproducibility was always more variable than the repeatability, which suggested some laboratory effects. The repeatability coefficient of disc diffusion was lowest for tetracycline (4.4 mm, 95% CI: 3.8-5.0 mm) and ampicillin (4.6 mm, 95% CI: 4.2-5.2 mm) and highest for trimethoprim-sulfamethoxazole (6.6 mm, 95% CI: 5.9-7.4 mm). The reproducibility coefficient of disc diffusion was lowest for gentamicin (5.4, 95% CI: 4.0-7.2) and highest for trimethoprim-sulfamethoxazole (7.2 mm, 95%CI: 4.5-11.7 mm). The precision of the disc diffusion assay was deemed satisfactory for use in a national surveillance program for clinical porcine E. coli isolates. However, measurement variation of the disc diffusion assay is of concern for isolates with marginal susceptibility or resistance due to increased risk of misclassification.
Identifiants
pubmed: 31586718
pii: S0167-5877(19)30362-9
doi: 10.1016/j.prevetmed.2019.104782
pii:
doi:
Substances chimiques
Anti-Bacterial Agents
0
Types de publication
Comparative Study
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
104782Informations de copyright
Copyright © 2019 Elsevier B.V. All rights reserved.